Skip Navigation
Skip to contents

ACC : Acute and Critical Care

OPEN ACCESS
SEARCH
Search

Search

Page Path
HOME > Search
1 "Manjini Jeyaram Kumari"
Filter
Filter
Article category
Keywords
Publication year
Authors
Original Article
Pulmonary
Under or overpressure: an audit of endotracheal cuff pressure monitoring at the tertiary care center
Biju Viswambharan, Manjini Jeyaram Kumari, Gopala Krishnan, Lakshmi Ramamoorthy
Acute Crit Care. 2021;36(4):374-379.   Published online November 26, 2021
DOI: https://doi.org/10.4266/acc.2021.00024
  • 4,870 View
  • 183 Download
  • 2 Web of Science
  • 3 Crossref
AbstractAbstract PDF
Background
Mechanical ventilation is a lifesaving intervention for critically ill patients but can produce the major complication of ventilator-associated pneumonia (VAP). Inappropriately inflated endotracheal tubes cause potential harm due to high or low pressure; this can be prevented through monitoring protocols.
Methods
A cross-sectional study of 348 cuff pressure readings was performed with intubated and mechanically ventilated patients to evaluate the exact proportion of patients in intensive care units (ICUs) where the cuff pressure is optimal and to identify the ICUs where device-based monitoring is available to produce a lower proportion of sub-optimal cuff pressure cases. Every three days, cuff pressure was assessed with a handheld cuff pressure manometer. The corresponding VAP rates of those ICUs were obtained from the hospital infection control department.
Results
Cuff pressure of 40.2% was the lower cutoff for the high category, that of optimal was 35.3%, and the highest cutoff of sub-optimal was 24.4%. This study also showed ICUs that had cuff pressure monitoring devices and protocols. Active measurement protocols had a higher proportion of optimal cuff pressure (58.5%) and a lower proportion of sub-optimal and high cuff pressure (19.5% and 22.0%) compared to ICUs with no device-based monitoring protocols. Furthermore, the VAP rate of ICUs exhibited a weak positive correlation with sub-optimal cuff pressure.
Conclusions
Device-based cuff pressure monitoring is essential in maintaining adequate cuff pressure but often is inadequate, resulting in high readings. Therefore, this study suggests that device-based cuff pressure monitoring be practiced.

Citations

Citations to this article as recorded by  
  • Pressure changes in the endotracheal tube cuff in otorhinolaryngologic surgery: a prospective observational study
    Sujung Park, Young In Kwon, Hyun Joo Kim
    Frontiers in Medicine.2023;[Epub]     CrossRef
  • Correlación entre la presión del manguito del tubo endotraqueal y los síntomas laringotraqueales en postoperatorio
    Wedley Peñaloza, Reyes Cruz Manuel Reyes, Evelin Núñez Wong
    Revista Gaceta Médica JBG.2023;[Epub]     CrossRef
  • Efficacy of using an intravenous catheter to repair damaged expansion lines of endotracheal tubes and laryngeal masks
    Tingting Wang, Jiang Wang, Yao Lu, Xuesheng Liu, Shangui Chen
    BMC Anesthesiology.2022;[Epub]     CrossRef

ACC : Acute and Critical Care